Texas City Final Report

9th Dec 2005 16:00

BP PLC09 December 2005 December 9, 2005 This press release was issued in Texas by BP Products North America Inc at 1000hrs local time on December 9, 2005 BP Issues Final Report on Fatal Explosion, Announces $1 billion Investment at Texas City HOUSTON -- BP Products North America Inc. today issued its final incidentinvestigation report on the March 23, 2005 Texas City Refinery explosion andfire that claimed the lives of 15 workers and injured many more. The company isimplementing the recommendations of the incident investigation team and amodernization program to secure the long term future of the refinery. Thecompany expects to invest an estimated $1 billion dollars to improve andmaintain the site over the next five years. "The report clearly describes the underlying causes and management systemfailures which contributed to the worst tragedy in BP's recent history," saidRoss Pillari, president of BP Products North America Inc. "We accept thefindings, and we are working to make Texas City a complex that attains thehighest levels of safety, reliability and environmental performance." Some of the actions recommended by the investigation team have been completed.Many are underway. Texas City site manager Colin Maclean has established aspecial project team to plan and drive execution of the improvement program. The company will install modern process control systems on major units,transition to a more powerful maintenance management system, improve workertraining, remove blow down stacks and implement the other recommendationscontained in the final report. The project team will also develop plans forreconfiguring and simplifying the operation of the Texas City refinery. "The result will be a safe, reliable and highly efficient refinery capable ofproducing clean fuels that consumers are demanding," Maclean said. In anticipation of a recommendation contained in the final report, BP hasstrengthened and changed the focus of its internal audit program to providegreater assurance that operations at Texas City and the company's four otherU.S. refineries adhere to company standards. The investigation team "found no evidence of anyone consciously or intentionallytaking actions or decisions that put others at risk." However, "the team foundmany areas where procedures, policies and expected behaviors were not met." According to the report, "the underlying reasons for the behaviors and actionsdisplayed during the incident are complex and the team has spent much timetrying to understand them. It is evident that they had been many years in themaking and will require concerted and committed actions to address." The final report confirms the critical factors which led to the explosion andgreatly increased its consequences. Those critical factors were identified in aninterim report published May 17. The final report also identifies the followingunderlying causes: * Over the years, the working environment had eroded to one characterized by resistance to change, and lacking of trust, motivation, and a sense of purpose. Coupled with unclear expectations around supervisory and management behaviors this meant that rules were not consistently followed, rigor was lacking and individuals felt disempowered from suggesting or initiating improvements. * Process safety, operations performance and systematic risk reduction priorities had not been set and consistently reinforced by management. * Many changes in a complex organization had led to the lack of clear accountabilities and poor communication, which together resulted in confusion in the workforce over roles and responsibilities. * A poor level of hazard awareness and understanding of process safety on the site resulted in people accepting levels of risk that are considerably higher than comparable installations. One consequence was that temporary office trailers were placed within 150 feet of a blowdown stack which vented heavier than air hydrocarbons to the atmosphere without questioning the established industry practice. * Given the poor vertical communication and performance management process, there was neither adequate early warning system of problems, nor any independent means of understanding the deteriorating standards in the plant. Prior to March 23, the leadership team at Texas City was working to address manyof the problems later described in the final investigation report. A control of work program had been started to ensure maintenance activities weresafely performed. Training for supervisors was being improved. A program toimplement a "Just Culture" in which people are held accountable for their jobperformance was getting underway. The workplace injury rate had been reduced bymore than 70 per cent. "We have recommended expansion, continuation and more rapid implementation ofsome initiatives already in progress at Texas City," said John Mogford, who ledthe investigation team and who serves as senior group vice president for safetyand operations. Maclean, who was named manager of the Texas City site May 17, has strengthenedthe leadership team at the refinery, bringing in new personnel from otherlocations in BP and reassigning others. He has simplified the organizationalstructure, clarified roles and responsibilities and put in place systems toimprove communication and compliance with procedures. "We are creating an environment in which people know that what they say matters,that they know what is expected of them and that they will deliver what isexpected of them," Maclean said. "We must keep our promises to each other. It isthe first step in rebuilding trust and the only way to earn the respect andobtain the commitment of a very skilled and very experienced workforce." BP's incident investigation was conducted by a team of BP operations, refiningand safety experts and salaried and union employees of the Texas City refinery.The team was directed to determine the cause of the March 23 explosion and makerecommendations for preventing similar incidents in the future. The final incident investigation report has been shared with government agenciesinvestigating the incident and the findings and recommendations are beingcommunicated across BP's global operations. As promised, the report is availableto the public and has been posted on the web at www.bpresponse.org. Notes to Editors * BP has accepted responsibility for the March 23 explosion and for the management system failures and employee mistakes which contributed to or caused the explosion. * The company has set aside $700 million to compensate victims of the explosion and has worked to resolve claims arising from the incident. Settlements have been achieved with the families of most of the workers who died and with many workers who suffered serious injuries. * BP has entered a settlement with the U.S. Occupational Safety and Health Administration resolving more than 300 separate alleged violations of OSHA safety regulations. BP paid a fine of $21.3 million. The company agreed to a number of corrective actions, including the hiring and placement of process safety and organizational experts at the refinery. Under the agreement, BP does not admit the alleged violations or agree with the way OSHA has characterized them. * BP continues to cooperate with the U.S. Chemical Safety and Hazard Investigation Board (CSB), the U.S. Environmental Protection Agency and the Texas Commission on Environmental Quality regarding the Texas City explosion and related concerns. * On the recommendation of the CSB, BP has voluntarily appointed an independent panel to assess and make recommendations for improvement of safety management and safety culture at the company's five U.S. refineries. Former U.S. Secretary of State James A. Baker is chairman of the panel. * BP has endorsed a CSB recommendation urging the industry to revisit existing standards for the use of temporary buildings inside refineries and other processing plants. BP has established a new standard for its refining operations and plans to share it with others in industry. * The Texas City refinery is owned and operated by BP Products North America Inc. It is BP's largest and most complex refinery with a rated capacity of 460,000 barrels per day and an ability to produce up to 11 million US gallons of gasoline per day. * The Isomerization (ISOM) unit is used to convert raffinate, a low octane blending feed, into higher octane components for unleaded regular gasoline. The unit has four sections including a splitter which takes raffinate and fractionates it into light and heavy components. The splitter consists of a surge drum, fired heater reboiler and a fractionating column 164 feet tall (50 metres). Description of incident The explosion and fire occurred after personnel responsible for the startupgreatly overfilled the raffinate splitter tower and overheated its contents,which resulted in over pressuring of its relief valves. Liquid was pumped into the tower for almost three hours without any liquid beingremoved or any action taken to achieve the lower liquid level mandated by thestartup procedure. The liquid level in the tower just prior to the loss of containment was at least20 times higher than it should have been. Activation of the automatic liquidlevel control, as mandated in the startup procedure, would have prevented thisoccurring. A decision late in the start up to begin removing liquid from the towerexacerbated the incident. Rapid heat exchange between the over heated liquidbeing removed from the bottom of the tower and the liquid feed continuing toflow into the tower (the two streams pass through a heat exchanger) causedsignificant vapor generation as the feed entered the tower. Vaporization of theliquid feed low in the tower pushed liquid up the tower and out of the unit,over pressuring the relief valves and ultimately overwhelming the adjacent blowdown unit. Based on process modeling, the investigation team estimates that about 1,100barrels of liquid was discharged to the blow down unit which has a capacity of390 barrels. Most of the liquid was released into the petroleum sewer system. Anestimated 50 barrels overflowed the tower and led to the formation of ahydrocarbon vapor cloud at ground level. Based on inspection of the sewer system and process and explosion modeling, theinvestigation team concluded that the sewers were not the primary route for theformation of the hydrocarbon vapor cloud that subsequently exploded. The damageobserved to the sewer system was the result of secondary fires caused by themain explosion. The source of ignition is not known. Unit supervisors were absent from the scene during critical parts of the startupand unit operators failed to take effective action to control the process upsetor to sound evacuation alarms after the pressure relief valves opened. Critical factors The final report confirms the critical factors which led to the explosion andgreatly increased its consequences. Those critical factors, which were describedin the interim investigation report issued May 17 are: * The failure to follow procedures, leading to greatly overfilling the raffinate splitter tower * Venting of liquids caused by overfilling and over heating of the liquid in the tower leading to a liquid relief to atmosphere and the subsequent explosion * The location of many people too close to the source of relief (a blow down unit), congregated in and around temporary trailers which were inappropriately sited * The continued use of a blow down unit for light-end hydrocarbon use when inherently safer options were available and could have been installed. For further information contact: Ronnie Chappell, BP Press Office, Houston: 281-366-5174 - ENDS - This information is provided by RNS The company news service from the London Stock Exchange

Related Shares:

BP
FTSE 100 Latest
Value8,328.60
Change0.00